- BLE GATT communication via bleak (UART-over-GATT, service 0xff00) - Parses 0x03 (general info) and 0x04 (cell voltages) frames - Protocol verified against official RS485/UART spec V4 - DataUpdateCoordinator with 5s poll interval (configurable 2-60s) - Auto-reconnect on BLE disconnect - Config flow: BT auto-discovery + manual MAC entry + options flow - Sensors: voltage, current, power, SoC, capacity, cycles, temps, cells, cell delta - HACS-ready (hacs.json, manifest.json) Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
131 lines
4.6 KiB
Python
131 lines
4.6 KiB
Python
"""Config flow for the Xiaoxiang Smart BMS integration."""
|
|
from __future__ import annotations
|
|
|
|
import voluptuous as vol
|
|
from homeassistant import config_entries
|
|
from homeassistant.components.bluetooth import (
|
|
BluetoothServiceInfoBleak,
|
|
async_discovered_service_info,
|
|
)
|
|
from homeassistant.core import callback
|
|
from homeassistant.data_entry_flow import FlowResult
|
|
|
|
from .const import (
|
|
CONF_ADDRESS,
|
|
CONF_POLL_INTERVAL,
|
|
DEFAULT_POLL_INTERVAL,
|
|
DOMAIN,
|
|
MAX_POLL_INTERVAL,
|
|
MIN_POLL_INTERVAL,
|
|
UART_SERVICE_UUID,
|
|
)
|
|
|
|
|
|
class XiaoxiangBmsConfigFlow(config_entries.ConfigFlow, domain=DOMAIN):
|
|
"""Handle a config flow for the Xiaoxiang Smart BMS."""
|
|
|
|
VERSION = 1
|
|
|
|
def __init__(self) -> None:
|
|
self._address: str | None = None
|
|
self._name: str | None = None
|
|
|
|
# ------------------------------------------------------------------
|
|
# Auto-discovery path (HA sees BMS advertising matching service UUID)
|
|
# ------------------------------------------------------------------
|
|
|
|
async def async_step_bluetooth(
|
|
self, discovery_info: BluetoothServiceInfoBleak
|
|
) -> FlowResult:
|
|
"""Handle BLE auto-discovery."""
|
|
self._address = discovery_info.address
|
|
self._name = discovery_info.name or f"Xiaoxiang BMS ({discovery_info.address})"
|
|
|
|
await self.async_set_unique_id(discovery_info.address)
|
|
self._abort_if_unique_id_configured()
|
|
|
|
self.context["title_placeholders"] = {"name": self._name}
|
|
return await self.async_step_confirm()
|
|
|
|
async def async_step_confirm(self, user_input: dict | None = None) -> FlowResult:
|
|
"""Confirm auto-discovered device."""
|
|
if user_input is not None:
|
|
return self.async_create_entry(
|
|
title=self._name,
|
|
data={CONF_ADDRESS: self._address},
|
|
)
|
|
return self.async_show_form(
|
|
step_id="confirm",
|
|
description_placeholders={
|
|
"name": self._name,
|
|
"address": self._address,
|
|
},
|
|
)
|
|
|
|
# ------------------------------------------------------------------
|
|
# Manual path (user goes to Integrations → Add → Xiaoxiang BMS)
|
|
# ------------------------------------------------------------------
|
|
|
|
async def async_step_user(self, user_input: dict | None = None) -> FlowResult:
|
|
"""Handle manual setup. Shows discovered BMS devices as a dropdown if found."""
|
|
errors: dict[str, str] = {}
|
|
|
|
if user_input is not None:
|
|
address = user_input[CONF_ADDRESS].upper().strip()
|
|
await self.async_set_unique_id(address)
|
|
self._abort_if_unique_id_configured()
|
|
return self.async_create_entry(
|
|
title=f"Xiaoxiang BMS ({address})",
|
|
data={CONF_ADDRESS: address},
|
|
)
|
|
|
|
# Build a dropdown of already-discovered BMS devices (filtered by service UUID)
|
|
discovered: dict[str, str] = {
|
|
info.address: f"{info.name or 'Xiaoxiang BMS'} ({info.address})"
|
|
for info in async_discovered_service_info(self.hass)
|
|
if UART_SERVICE_UUID in (info.service_uuids or [])
|
|
}
|
|
|
|
if discovered:
|
|
schema = vol.Schema({vol.Required(CONF_ADDRESS): vol.In(discovered)})
|
|
else:
|
|
schema = vol.Schema({
|
|
vol.Required(CONF_ADDRESS): str,
|
|
})
|
|
|
|
return self.async_show_form(
|
|
step_id="user",
|
|
data_schema=schema,
|
|
errors=errors,
|
|
)
|
|
|
|
# ------------------------------------------------------------------
|
|
# Options flow (change poll interval after setup)
|
|
# ------------------------------------------------------------------
|
|
|
|
@staticmethod
|
|
@callback
|
|
def async_get_options_flow(config_entry: config_entries.ConfigEntry) -> BmsOptionsFlow:
|
|
return BmsOptionsFlow(config_entry)
|
|
|
|
|
|
class BmsOptionsFlow(config_entries.OptionsFlow):
|
|
"""Allow the user to change the poll interval after initial setup."""
|
|
|
|
def __init__(self, config_entry: config_entries.ConfigEntry) -> None:
|
|
self._config_entry = config_entry
|
|
|
|
async def async_step_init(self, user_input: dict | None = None) -> FlowResult:
|
|
if user_input is not None:
|
|
return self.async_create_entry(title="", data=user_input)
|
|
|
|
current = self._config_entry.options.get(CONF_POLL_INTERVAL, DEFAULT_POLL_INTERVAL)
|
|
return self.async_show_form(
|
|
step_id="init",
|
|
data_schema=vol.Schema({
|
|
vol.Required(CONF_POLL_INTERVAL, default=current): vol.All(
|
|
int, vol.Range(min=MIN_POLL_INTERVAL, max=MAX_POLL_INTERVAL)
|
|
),
|
|
}),
|
|
)
|