Prevent unavailable oscillation with failure tolerance
- Track consecutive failures; return cached data for up to 3 misses in a row before marking sensors unavailable. Single transient BLE failures no longer cause the UI to flip unavailable. - Retry device lookup: if async_ble_device_from_address returns None (device not yet back in scanner cache after last disconnect), wait 2s and try once more before counting it as a failure. Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
This commit is contained in:
@@ -15,6 +15,11 @@ from .const import CMD_CELL, CMD_GENERAL, CMD_VERSION, DOMAIN
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
# Only mark sensors unavailable after this many *consecutive* failed polls.
|
||||
# Transient BLE misses (device not in cache, ESPHome proxy busy, etc.) return
|
||||
# the last known data instead so the UI doesn't oscillate.
|
||||
_FAILURES_BEFORE_UNAVAILABLE = 3
|
||||
|
||||
|
||||
class BmsCoordinator(DataUpdateCoordinator[dict]):
|
||||
"""Polls the BMS over BLE and distributes data to all sensor entities.
|
||||
@@ -38,9 +43,10 @@ class BmsCoordinator(DataUpdateCoordinator[dict]):
|
||||
)
|
||||
self.address = address
|
||||
self._device_name = name
|
||||
self._poll_timeout = max(poll_interval - 3, 10) # hard cap, leaves 3s slack
|
||||
self._poll_timeout = max(poll_interval - 3, 10)
|
||||
self._handler = BmsBluetoothHandler(address)
|
||||
self.hw_version: str | None = None
|
||||
self._consecutive_failures = 0
|
||||
|
||||
# ------------------------------------------------------------------
|
||||
# Device info — shared by sensor, binary_sensor, number platforms
|
||||
@@ -69,15 +75,39 @@ class BmsCoordinator(DataUpdateCoordinator[dict]):
|
||||
# Poll
|
||||
# ------------------------------------------------------------------
|
||||
|
||||
def _handle_failure(self, reason: str) -> dict:
|
||||
"""On a transient failure, return cached data up to the threshold.
|
||||
|
||||
Only raises UpdateFailed (→ sensors go unavailable) after
|
||||
_FAILURES_BEFORE_UNAVAILABLE consecutive misses.
|
||||
"""
|
||||
self._consecutive_failures += 1
|
||||
if self._consecutive_failures <= _FAILURES_BEFORE_UNAVAILABLE and self.data:
|
||||
_LOGGER.debug(
|
||||
"BMS poll failed (%d/%d), keeping last known data: %s",
|
||||
self._consecutive_failures,
|
||||
_FAILURES_BEFORE_UNAVAILABLE,
|
||||
reason,
|
||||
)
|
||||
return self.data
|
||||
raise UpdateFailed(reason)
|
||||
|
||||
async def _async_update_data(self) -> dict:
|
||||
"""Connect to the BMS, fetch all data, disconnect."""
|
||||
|
||||
# The BMS may not be in the scanner cache immediately after a disconnect.
|
||||
# Wait up to 2 s for an advertisement before giving up.
|
||||
device = async_ble_device_from_address(self.hass, self.address, connectable=True)
|
||||
if device is None:
|
||||
raise UpdateFailed(
|
||||
await asyncio.sleep(2.0)
|
||||
device = async_ble_device_from_address(
|
||||
self.hass, self.address, connectable=True
|
||||
)
|
||||
if device is None:
|
||||
return self._handle_failure(
|
||||
f"BMS ({self.address}) not reachable — check Bluetooth adapter / proxy"
|
||||
)
|
||||
|
||||
# Fetch hardware version once; skip on subsequent polls
|
||||
commands = [CMD_GENERAL, CMD_CELL]
|
||||
if self.hw_version is None:
|
||||
commands.append(CMD_VERSION)
|
||||
@@ -88,18 +118,21 @@ class BmsCoordinator(DataUpdateCoordinator[dict]):
|
||||
timeout=self._poll_timeout,
|
||||
)
|
||||
except asyncio.TimeoutError:
|
||||
raise UpdateFailed(
|
||||
return self._handle_failure(
|
||||
f"BMS poll timed out after {self._poll_timeout}s"
|
||||
)
|
||||
except Exception as exc:
|
||||
raise UpdateFailed(f"BMS poll failed: {exc}") from exc
|
||||
return self._handle_failure(f"BMS poll failed: {exc}")
|
||||
|
||||
general_frame, cell_frame = responses[0], responses[1]
|
||||
|
||||
if general_frame is None:
|
||||
raise UpdateFailed("No response to general info request (0x03)")
|
||||
return self._handle_failure("No response to general info request (0x03)")
|
||||
if cell_frame is None:
|
||||
raise UpdateFailed("No response to cell info request (0x04)")
|
||||
return self._handle_failure("No response to cell info request (0x04)")
|
||||
|
||||
# Successful poll — reset failure counter
|
||||
self._consecutive_failures = 0
|
||||
|
||||
if self.hw_version is None and len(responses) > 2 and responses[2]:
|
||||
self.hw_version = BmsBluetoothHandler.parse_version(responses[2])
|
||||
@@ -108,7 +141,6 @@ class BmsCoordinator(DataUpdateCoordinator[dict]):
|
||||
data = BmsBluetoothHandler.parse_general_info(general_frame)
|
||||
data.update(BmsBluetoothHandler.parse_cell_info(cell_frame))
|
||||
|
||||
# Derived fields
|
||||
data["power"] = round(data["voltage"] * data["current"], 2)
|
||||
data["energy_stored"] = round(data["voltage"] * data["residual_capacity"] / 1000, 3)
|
||||
|
||||
|
||||
Reference in New Issue